E3.2 Traceable Measurements of Harmonic (2 – 150 kHz) Emissions in Smart Grids
- Event
- SMSI 2020
-
(did not take place because of Covid-19 virus pandemic) - Band
- SMSI 2020 - System of Units and Metrological Infrastructure
- Chapter
- E3 Traceability, New Calibration and Testing Methods
- Author(s)
- D. Istrate, D. Amaripadath - LNE, Trappes (France), E. Toutain - EDF, Moret-sur-Loing (France), R. Roche, F. Gao - Univ. Bourgogne Franche-Comté, Belfort (France)
- Pages
- 372 - 373
- DOI
- 10.5162/SMSI2020/E3.2
- ISBN
- 978-3-9819376-2-6
- Price
- free
Abstract
The paper aims to study the supraharmonic emissions in the frequency range of 2 to 150 kHz. The research applied the design of experience approach and a statistically based analysis method to identify the sources of the supraharmonic emission from field measurements on a smart grid. A generic waveform platform was designed and metrological characterized both for the generation and for the acquisition part. The characterization was done in the French Electrical Metrology Laboratory, the obtained expanded uncertainty is ± 1% for the harmonic amplitude.