SENSOR+TEST Conferences 2009 |
A4.3 - Compact Coriolis Mass Flow Meter/Controller for Low Flows |
M. Katerberg - Bronkhorst Cori-Tech B.V., Ruurlo, Netherlands |
SENSOR+TEST Conferences 2009 |
A4.4 - Left-Handed Transmission Line Mass Flow Meter for Particulate Solids in Pipelines |
A. Penirschke, M. Puentes, M. Schuessler, R. Jakoby - Technische Universität Darmstadt, Darmstadt, Germany |
SENSOR+TEST Conferences 2009 |
A5.1 - Intensity Determination of Cavitation at Rotating Pumps by Means of Integrated Miniaturised Pressure Transducers |
R. Werner, R. Werthschuetzky - Technische Universität Darmstadt, Darmstadt, Germany |
SENSOR+TEST Conferences 2009 |
A5.2 - RoboTouch - An Artificial Skin for Human-Robot Interaction |
M. Fritzsche, N. Elkmann - Fraunhofer Institute for Factory Operation and Automation, Magdeburg, Germany |
SENSOR+TEST Conferences 2009 |
A5.3 - Optical Sensor for Flow Measurement in Microstructures |
J. Zosel, U. Guth - Kurt-Schwabe Research Institute, Ziegra-Knobelsdorf, Germany, D. Petrak, H. Rauh - Chemnitz University of Technology, Chemnitz, Germany |
SENSOR+TEST Conferences 2009 |
A5.4 - Simplified and Miniaturized Laser Doppler Distance Sensor for Dynamic Position and Shape Measurement at Rotating Objects |
T. Pfister, L. Buettner, J. Czarske - Technische Universität Dresden, Dresden, Germany |
SENSOR+TEST Conferences 2009 |
B1.1 - Pressure Measurement by Medical Devices and within Medical Devices |
R. Glocker - MHM Harzbecher Medizintechnik GmbH, Aschaffenburg, Germany |
SENSOR+TEST Conferences 2009 |
B1.2 - HYPER-IMS: A Fully Implantable Blood Pressure Sensor for Hypertensive Patients |
M. Graefe, T. Goettsche, P. Osypka - Dr. Osypka GmbH Medizintechnik, Rheinfelden, Germany, M. Goertz, K. Trieu - Fraunhofer Institute für Mikroelektronische Schaltungen und Systeme, Duisburg, Germany, H. Fassbender, W. Mokwa, U. Urban, T. Schmitz-Rode - RWTH Aachen University, Aachen, Germany, T. Hilbel, R. Becker - Krehl-Klinik, Heidelberg, Germany, B. Bender, W. Coenen - Bytec Medizintechnik GmbH, Stolberg, Germany, M. Faehnle, R. Glocker - MHM Harzbecher Medizintechnik GmbH, Aschaffenburg, Germany |
SENSOR+TEST Conferences 2009 |
B1.3 - Excitation and Wireless Lock-In Measurement of Hip Prosthesis Vibrations for Loosening Detection |
U. Marschner - Technische Universität Dresden, Dresden, Germany, B. Jettkant - BG-Kliniken Bergmannsheil, Bochum, Germany, H. Graetz - Fraunhofer Institut für Photonische Mikrosysteme IPMS, Dresden, Germany, D. Ruwisch - Ruwisch & Kollegen GmbH, Berlin, Germany, W. Fischer - Technische Universität Dresden, Dresden, Germany, G. Woldt - Microelectronic Packaging Dresden GmbH, Dresden, Germany, B. Clasbrummel - Ev. Krankenhaus Witten im Diakoniewerk Ruhr, Witten, Germany |
SENSOR+TEST Conferences 2009 |
B1.4 - A Fully Implantable Epiretinal Vision Prosthesis for Retinitis Pigmentosa Patients |
T. Schanze, U. Thomas - EpiRet GmbH, Gießen, Germany |