2025 SMSI Bannerklein

PT1.56 - Method for Increasing Amplitude of Cluster Dither in RLG-based Small-size Inertial Measurement Unit

Event
EUROSENSORS XXXVI
2024-09-01 - 2024-09-04
Debrecen (Hungary)
Band
Poster
Chapter
PT1 - Theory, Modelling, Design and Testing
Author(s)
J. E. An, C. Kim, K. H. Chong - Agency for Defense Development, Daejeon (South Korea)
Pages
231 - 232
DOI
10.5162/EUROSENSORSXXXVI/PT1.56
ISBN
978-3-910600-03-4
Price
free

Abstract

The lock-in problem affecting ring laser gyroscopes (RLGs) is typically alleviated by applying a mechan-ical vibration to the RLG body using a dither. A cluster dither, which can excite three RLGs simultane-ously, can facilitate the miniaturization of RLG-based inertial measurement units (IMUs). This study examines the mechanical parameters of an IMU that affect the amplitude of the cluster dither. For this purpose, a model with two linearly damped coupled linear oscillators was used, and the theoretical analysis results were experimentally validated.