2025 SMSI Bannerklein

PT7.306 - Stationary Gas Sensor Networks for Continuous Leakage Detection

Event
EUROSENSORS XXXVI
2024-09-01 - 2024-09-04
Debrecen (Hungary)
Band
Poster
Chapter
PT7 - Photonics and Optical Microsystems
Author(s)
D. Marín López, J. Fonollosa - Universitat Politècnica de Catalunya, Barcelona (Spain), G. Rodriguez Gutierrez, X. Zhou, A. Ortiz Perez, S. Palzer - TU Dortmund, Dortmund (Germany)
Pages
489 - 490
DOI
10.5162/EUROSENSORSXXXVI/PT7.306
ISBN
978-3-910600-03-4
Price
free

Abstract

Continuous monitoring of Biogas installations is a means to improve safety and detect failures occurring only under specific operational conditions. Stationary methane sensor networks are able to perform this task by providing temporarily and spatially resolved data on methane concentrations. Therefore, the reliability and precision of the concentration data of individual nodes is paramount. This contribution presents the setting up of such a wireless gas sensor network based on a miniaturized, photoacoustic methane detection approach via multi-unit calibration. The results highlight the importance and potential of reliable calibration methods as basis for gas flux measurements using stationary sensor nodes.